3. Specifications

3. Specifications

3.1 Measuring ranges

EN
Gauge pressure
bar
Measuring range
Overload safety
Burst pressure
psi
Measuring range
Overload safety
Burst pressure
Vacuum tightness: Yes

3.2 Output signals

Signal type
Current (2-wire)
Voltage (3-wire)
Ratiometric (3-wire)
Depending on the signal the following loads apply:
Signal
4 ... 20 mA
DC 0 ... 10 V
DC 0 ... 5 V
DC 1 ... 5 V
DC 0.5 ... 4.5 V ratiometric
8
0 ... 6
0 ... 10
20
20
25
25
0 ... 100
0 ... 150
290
290
1,450
1,450
Signal
4 ... 20 mA
DC 0 ... 10 V
DC 0 ... 5 V
DC 1 ... 5 V
DC 0.5 ... 4.5 V
Load in Ω
≤ (power supply - 8 V) / 0.02 A
> max. signal / 1 mA
> max. signal / 1 mA
> max. signal / 1 mA
> max. signal / 1 mA
0 ... 16
0 ... 200
32
500
160
1,200
0 ... 200
0 ... 3,000
460
7,200
2,300
17,000
WIKA operating instructions, model MG-1
0 ... 300
0 ... 400
800
800
1,700
1,700
0 ... 4,000
0 ... 5,000
11,000
11,000
24,000
24,000