This product should not be disposed along with normal domestic
waste at the end of its service life but should be handed over at a
collection point for recycling electrical and electronic devices.
CAT I
This device is designed for measurements on electric circuits,
which are not directly connected to the public power grid like
measurements in circuits that are not derived from the power grid
and specially protected circuits that are derived from the power
grid.
CAT II
The device is designed for making measurements in circuits that
are directly connected to the low voltage network electrically, for
e.g. measurements on household appliances, mobile tools and
similar devices.
CAT III
The device is designed for making measurements in building
installations. Examples are measurements on junction boards,
circuit breakers, wiring, switches, permanently installed sockets,
devices for industrial use as well as permanently installed motors.
CAT IV
The device is designed for making measurements at sources of
low voltage installations. Examples are meters and measurements
on primary overload protection devices and ripple control devices.
DC current / voltage according to IEC 60417‐5032
AC current / voltage according to IEC 60417‐5032
Ω
Resistance
Diode test
Capacitance test
Audible continuity tester
Battery low
Ground / Earth
EN 6