Herunterladen Inhalt Inhalt Diese Seite drucken

FLUX FMJ 100 Betriebsanleitung Seite 24

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2
FLUXTRONIC
The electronic analysis unit displays the volume of liquid that has flown through a flow
meter.
The nutating disc meter generates pulses by volume (e.g. 0.05 L/pulse). The pulses are
registered by the electronic analysis unit and converted into the actual volume via a
calibration constant.
Number of pulses x Calibration constant = Volume.
Keep organic solvents away from the keyboard and LCD display.
Stop
Process
2.1
Operating the FLUXTRONIC
The FLUXTRONIC contains five menu items.
The user can switch between the items at any time using the Up and Down keys. The
key figure for each respective item is displayed.
1. BC RUN: The volume to be filled is displayed
2. TOT: The total volume is displayed
3. FLO: The flow rate is displayed
4. CAL 0: The current calibration constant is displayed
5. SET: General settings
5
SET
24 / 60
Display
1 Default display
RUN
4
CAL
Attachment FLUXTRONIC FMJ 100
Unit block
Information line
OK
left/right
up/down
2
TOT
Process
3
FLO
Stop