Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Incorrect installation
• Keeping exhaust pipe is of great importance, and incorrect instal-
lation will affect normal operation of the air conditioner; During
installation substantial bend of exhaust pipe is prohibited; Gua-
rantee smooth air flow inside the pipe.
• The length of exhaust pipe is especially designed for this type and
should not be replaced or extended without permission, otherwise
failure may be caused.
• The max spread length of exhaust pipe is 1500mm, please reduce
the length as much as possible during use, and remaining exhaust.
Remote control
Before use of remote control, please install cells in correct way. The
specific steps are as follows:
• Slide the cell cover on the back of remote control open;
• Insert two new No.7 alkaline cells, and make sure that the polarity
is correct.
• Click the cell cover in place.
Attention: Only No.7 alkaline cells can be used for remote control of
this machine, and rechargeable cells or other models are not allowed
for use; Two cells should be replaced simultaneously, and mixing of
new and old cells is prohibited'. If the air conditioner is in idle for long
time, please take the cells out of remote control. Please do not use
the cells if leakage is found; If fluid flows on skin or clothes careless-
ly, please wash with fresh water immediately.
Refrigeration mode
After power-on startup take refrigeration mode as default or press mode key to select refrigeration
mode, and refrigeration indicator lamp is on. Pressing UP/DOWN key can regulate setting tempera-
ture (17°C~30°C). Pressing air speed key can select high, medium or low air speed.
Air supply mode
Pressing air speed key can select high or medium or low air speed. Temperature cannot be set.
Dehumidification mode
• Select dehumidification mode by pressing mode key or by means of remote control; and humidi-
fication indicator lamp is on.
• At the beginning of entry into dehumidification mode, if the room temperature is 15°C, compressor
starts. After that control as the following rules: when the room temperature is 13°C, compressor
shuts down; as the temperature rises again to the room temperature 15°C, compressor restarts
(3min time-delay protective function must be satisfied).
• In dehumidification mode, the fan runs at low speed in default and air speed cannot be regulated.
Temperature cannot be set.
Usage tip: for use of dehumidification function, exhaust pipe assembly should be removed, other-
wise the dehumidification effect becomes less obvious and flash alarm display of "FL" full water ap-
pears.

Use and Functions

12

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis