Remote Controller
1. Slide the battery cover on the back of the remote controller to open.
2. Insert 2 new alkaline 7th batteries. When inserted, their terminals shall be
ensured to be installed correctly.
3. Put the battery cover into place.
Important Hints on Using Batteries
• The remote controller only uses 7th alkaline bateries. Do not use rechargable or other types of
batteries.
• When replacing the batteries, replace both. Do not mix old and new batteries in use.
• If the air conditioner is not used for a long time, remove the batteries from the remote controller.
• If there is battery leakage, do not the battery.
• Chemicals inside the battery may cause burns or other health hazards; if their liquid flows to the
skin or clothing, rinse with water immediately; if eating it accidentally, gargle with water immedi-
ately, and then go to a hospital and see a doctor for further examination.
Refrigeration mode
• After being powered and turned on, its refrigeration mode or pressing mode button to select refri-
geration mode by default, and the refrigeration indicator light is on.
• Press the up or down button to adjust the settled temperature (16°C-30°C).
• Press the wind speed button to select high, medium or low wind speed.
Air distribution mode
• Press the mode button or via the remote controller to select air distribution mode, and air distri-
bution indicator light is on.
• Press the wind speed button to select high, medium or low wind speed.
• Temperature cannot be set.
Dehumidification mode
• Select dehumidification mode by pressing mode button or via remote
controller, and the dehumidification indicator light is on.
• As shown in the picture below, remove the plug of drainage outfall, insert
the aqueduct, and put another end of the aqueduct into water containers
or drain channels.
• When entering dehumidification mode, if the room temperature is ≥17°C
(or 62°F), the compressor will start to work. Then control according to
the following rules: when room temperature is ≤15°C, compressor stops;
when the temperature rises back to ≥17°C (59°F), the compressor re-
starts (the restart of compressor shall meet the 3-minute delay protection
function).
• In dehumidification mode, the fan run in low speed by default, and the
wind speed are not adjustable.
• Temperature cannot be set.
NOTE: When the dehumidification function is in use, the exhaust pipe assembly shall be removed;