Herunterladen Inhalt Inhalt Diese Seite drucken

Operation And Settings; Replacement Parts - Grohe EUROECO COSMOPOLITAN E 36 409 Handbuch

Vorschau ausblenden Andere Handbücher für EUROECO COSMOPOLITAN E 36 409:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
®
Bluetooth
:
• Power consumption:
• Output:
®
• Bluetooth
- version:
® -
• Bluetooth
Transmission distance:
(depending on the environments)
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Installation
, see fold-out page I - II.
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
®
Bluetooth
Connection not
• No reception/connection interrupted
possible
• Interferences in the reception area
• Obstacle in transmission path
• Water is flowing / Object detection
Interrupted while
• Interferences in the reception area
operating
• Obstacle in transmission path
3

Operation and settings,

1 W
see technical product information, 99.0409.xxx /
®
Bluetooth
- Class 2
99.0438.xxx
4.0
Activating setting mode
about 10m
Disconnect the power supply to the electronics and reconnect
after 10 s.
60 s
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
1 s
approaching user.
Setting mode is automatically terminated after 3 minutes..
12cm
Maintenance
•Shut off water supply.
•Disconnect voltage supply.
A
2
•Inspect and clean all components and replace if
necessary.
2500 V
100 °C
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.

Replacement parts

see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Turn back the device to receiving range
- Turn off the source of interference
- Remove from radio path
- The detection zone must kept clear
- Turn off the source of interference
- Remove from radio path
, see fold-out page II.
accessory, prod. no.: 36 407) / app
(observe manufacturer´s documentation)
(observe manufacturer´s documentation)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis