To change the Filter: (See also Section C)
> Open the door of the under sink unit.
> Relieve system pressure via the filter flush stop cock, a quick
open and close will do. Use the bucket to catch the discharge.
> Grasp filter cartridge, depress the red lever at the top right of
the filter and rotate the cartridge a quarter turn to the left, then
gently pull down.
> Caution: a small amount of water will drip as the cartridge is
removed.
> Do not tilt the cartridge as water may spill from it if tilted.
> Unpack replacement cartridge and remove sanitary cap, write
today's date where shown on the label.
> Avoid touching the filter O-rings and filter opening as this may
cause bacterial contamination of the cartridge.
> Moisten the O-rings with water, align the front cartridge label to
the left (as shown in the "insert filter" diagram for filter cartridge
replacement), and push the new cartridge into the filter head.
> Turn the cartridge a quarter turn to the right until the cartridge
comes to complete stop and is locked into position, with the
front label facing forward.
> Initiate the filter flush programme by scrolling through the menu
screen (See section C).
> When completed, wipe up any spills and dispose of spent filter
cartridge and packaging thoughtfully.
> Close the door to secure the appliance.
> Adjust the filter settings in section F - filter - litres and days used.

General Cleaning

Do not use strong, corrosive, spray or abrasive cleaners. Clean with
a soft damp cloth and mild soap.
Under sink units must never be located near, or cleaned with water
jets.
Avoid using air bourne pesticides near the undersink unit.
Filter Maintenance