6. Cleaning and Maintenance

1
1
2
2

Cleaning

The plastic surfaces and taps should be wiped with a slightly wet and hygienic cloth
only. Do not use abrasive or chlorine­based cleaning agents or solvents.
To prevent damage of the electronic components do not clean the undersink unit and
tap with a water jet.

Filter replacement

The white LED on the tap will flash either after the filter has been in use for 12 months
or after 4,000 litres of water have been filtered, indicating that the filter needs to be
replaced. The filter may have to be replaced earlier if an unpleasant odour or taste
occurs.
Water may drip out of the filter holder during replacement. Have a bucket and cloths
ready to mop up any water that escapes.
1. Close the angle valve to shut off the water supply.
2. Turn the filter cartridge one quarter turn anticlockwise, as far as it will go.
3. Carefully pull the filter cartridge out of the filter holder from below. Hold the
cartridge level to avoid spilling dirty water.
4. Unpack the new filter cartridge and write today's date in the space provided at
the label. Avoid contact with the O­rings and filter opening, as that could result in
bacterial contamination of the filter.
5. Push a new replacement filter cartridge into the filter holder and turn it clockwise as
far as it will go to lock it in position.
6. To flush the filter, detach the hose from the water inlet of the undersink unit and
hold it over a drain or bucket. Open the isolating valve and allow the water to run
for several minutes.
7. Then close the isolating valve and reattach the hose to the water inlet of the
undersink unit.
8. Open the isolating valve to re­establish the water flow to the unit.
9. Press the red and the blue levers on the tap simultaneously and hold for 10 seconds
to reset the filter replacement indicator. The white LED will remain lit for the
ten seconds before going out again.
10. Dispose of the used filter correctly.

Further maintenance

Regular servicing is necessary to keep the unit working efficiently at all times. Please
contact customer service for more information.
Sign a maintenance contract with us. Our customer service will contact you in good
time before the next due maintenance to arrange an appointment with you.
We offer a filter service where we can determine your consumption with you and
contact you in good time before reaching the calculated filter capacity.