Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Activating cleaning mode,
see page 2.
Triggering flushing and signalling status,
see page 2.
*F: Solenoid valve intact / defective
*G: Temperature sensor intact / defective
Making settings
, see page 3
Activating setting mode, see Fig [1].
Setting the flow volume, see Fig. [2a] .
Setting the programme, see Fig. [2b].
Observe programme table, see fold-out page I.
Setting mode is automatically terminated after 3 minutes.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Power supply unit defective
- Power supply switched off
• Outlet clogged
• Temperature sensor defective
• Through high ambient temperature, the
water temperature in the siphon and in the
water supply is > 35 °C
• Flushing during continuous use is activated
(Flushing is initiated every 8 min.
independent of the use)
Undesired water
• Automatic flushing activated
flow
• Through high ambient temperature, the
water temperature in the siphon is > 35 ° C
• Solenoid valve defective
Flow volume too
• Solenoid valve defective
low
• Filter in solenoid valve blocked
®
Bluetooth
Connection not
• No reception/connection interrupted
possible
• Interferences in the reception area
• Obstacle in transmission path
Interrupted while
• Interferences in the reception area
operating
• Obstacle in transmission path
Maintenance
, see page 4
Demounting ceramic and shut off water supply,
see Fig. [1] and [2].
Inspect and clean all components and replace if necessary.
I. Power supply unit, see Fig. [3]
II. Solenoid valve and filter, see Fig. [4].
III. Siphon with temperature sensor, see Fig. [5].
IV. Electronic, see Fig. [6].
Assamble in reverse order.

Replacement parts

see fold-out page I

Disposal note

This category of device does not belong in the
domestic waste, but must be disposed of separately
in accordance with the relevant national regulations.
Remedy
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Switch on voltage supply
- Clean outlet
- Replace siphon with temperature sensor
- Ensure operating temperature of the water in the
water supply
- After drop of the temperature in the siphon the
elektronic terminates the mode flushing during
continuous use automatically
- The elektronic triggers a flushing to reduce the
water temperature in the siphon
- Replace solenoid valve
- Replace solenoid valve
- Clean filter
- Turn back the device to receiving range
- Turn off the source of interference
(observe manufacturer´s documentation)
- Remove from radio path
- Turn off the source of interference
(observe manufacturer´s documentation)
- Remove from radio path
8

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

39 369

Inhaltsverzeichnis