Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes; Technical Data; Replacement Parts - Grohe EUROSMART 23975003 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB

Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be replaced
by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Technical data

• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape (7 - 20 cm adjustable):
Thermal disinfection possible
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
Undesired water
• Sensor system detection zone set too high
flow
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filters in connection hose dirty
• Non-return valve defective
Automatic flush
• Safety shutdown active
does not work
• Ambient conditions not suitable
6V lithium battery type CR-P2
- Battery discharged
(indicator lamp lights up continuously)
for local conditions
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Operation and settings,
see technical product information 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
60 s
Maintenance
1 s
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
12 cm

Replacement parts

(* = special accessories)
Care
A
For directions on the care of this fitting, please refer to the
2
accompanying Care Instructions.
2500 V
100 °C
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector electronics and solenoid
valve
- Replace battery
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Replace the non-return valve
- Remove object
- Check ambient conditions with remote control
(special accessory, order no.: 36 407) in test mode
at maximum range, LED must not light up.