OPERATION
Settings
4.5.3 Programs
„Pro
The appliance offers the option to set 21 time programs. Switch
between the time programs using the Touch-Wheel. Press the "OK"
button to switch to setting a time program.
Time pro-
x.1
gram    x
Day or group of 
days
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Setting a time program begins with selecting a day of the week or
a group of days. Press "OK". Set the day using the Touch-Wheel.
Confirm with the "OK" button.
Use the Touch-Wheel to switch to setting the fan stage. Press
"OK". Set the fan stage in which the appliance runs when the
time program takes effect using the Touch-Wheel. Confirm with
the "OK" button.
Note
You cannot switch on fan stage 3 with time programs.
Use the Touch-Wheel to switch to setting the start time. Press
"OK". Set the start time of the respective time program using the
Touch-Wheel. Confirm with the "OK" button.
Use the Touch-Wheel to switch to setting the stop time. Press
"OK". Set the stop time of the respective time program using the
Touch-Wheel. Confirm with the "OK" button.
To delete a time program, go to the menu item where the day or
group of days is selected for the respective time program. Turn the
Touch-Wheel anti-clockwise until the day disappears and dashes
appear in the lower section of the display.
Note
In the case of overlapping time programs, the program
with the highest number takes priority.
www.stiebel-eltron.com 
x.2
x.3
x.4
Fan stage
Start time Stop time
Note
At times where there is no time program defined, the
appliance runs in set fan stage 2.
Example
Time scale
Monday - Friday
06:00 - 22:00
22:00 - 06:00
Saturday , Sunday
07:00 - 23:00
23:00 - 07:00
x
x.1
Day or group of 
days
1
1/2/3/4/5
2
1/2/3/4/5
3
6/7
4
6/7
4.5.4 Code
„Cod
You can use this menu item to enable actual values and parame-
ters, which are reserved for qualified contractors.
Options Effect
A0
The only parameters displayed are those that have been released
for the appliance user and can therefore be accessed without a
code.
A1
Parameters for qualified contractors
A2
Parameters for service department
A1 or A2 is shown on the display when you enter the correct
four-digit code.
If you switch to the actual values or parameters, you see the en-
abled parameters.
Note
After entering the code, switch to the menu by pressing
the "MENU" button. If you first switch to the standard
display by pressing the "HOME" button, the parameter
block is reactivated.
4.6

Switching off the appliance

Material losses
!
If you interrupt the power supply to the appliance, check
that humidity protection is ensured for the building.
The appliance has no ON/OFF switch. Disconnect the power supply
at the fuse/MCB in the domestic distribution board.
Stage
2
1
2
1
x.2
x.3
x.4
Fan stage
Start 
Stop time
time
1
22:00
00:00
1
00:00
06:00
1
23:00
00:00
1
00:00
07:00
LWZ 130  |