OPERATION
Settings
4.2.2 Display
If no user action occurs within the time selected in the illumi-
nation duration parameter, the display backlighting switches off
and the standard display appears. Press any button to switch the
background lighting on again.
Symbol Description
Power : This symbol indicates that the appliance is switched on and
the fans are operating in "humidity protection" mode.
Time : This symbol indicates that the appliance is operating in time
program mode. Depending on the program, the appliance is oper-
ated at different fan stages.
Fan : This symbol, with the associated digit, indicates the fan stage
at which the appliance is currently running.
Passive cooling : If the conditions for passive cooling are met, the
symbol illuminates. This does not signify that passive cooling is
already active. The symbol prompts you to open the window. If the
symbol goes out, you can close the window again.
This symbol is displayed when the function block is activated. Press
the "HOME" and "OK" buttons simultaneously for two seconds to
deactivate the function block.
Filters : Change the filter when this symbol appears.
Frost protection : This symbol is displayed when the appliance has
turned on the preheating coil for frost protection.
Service/fault : The "service/fault" symbol illuminates permanently
in the event of faults that do not impair the basic function of the
appliance. The "service/fault" symbol flashes if a serious fault has
occurred. Call your qualified contractor.
4.3
Selecting the fan stage
From the home screen, you can use the Touch-Wheel to select fan
stages 0, 1 and 2. The set value is accepted without you having to
press a button to confirm it.
You cannot activate intensive ventilation with the Touch-Wheel.
To switch on intensive ventilation, press the "intensive ventilation"
button for approx. one second. When intensive ventilation is ac-
tivated, the "intensive ventilation" indicator illuminates. You can
activate intensive ventilation with an external switch or with the
"intensive ventilation" button. You can only deactivate intensive
ventilation with the "intensive ventilation" button.
If you set fan stage 0, the appliance switches to a 24 hour dormant
phase. The humidity protection control unit only starts after this.
The qualified contractor can configure the humidity protection
control unit with parameters.
4.4
Activating time programs
The "time" symbol indicates that time programs are activated.
If the time programs are not activated, turn the Touch-Wheel
clockwise to switch from the home screen. After fan stage 2, the
fan stage set in the time program appears along with the "time"
symbol.
Note
If you switch the appliance to time program operation,
time programs must be entered in the "prog" menu. Oth-
erwise the appliance continues to run without a time limit
in set fan stage 2.
Enter the time program settings in the menu.
At times where there is no time program defined, the appliance
runs in set fan stage 2.
www.stiebel-eltron.com 
4.5
Menu
Display
Description
P1 - Pxx
Parameter
I1 - Ixx
Actual values
Pro
Programs
Cod
Entry of the code for unlocking protected parameters and actual
values
f To access the parameters, press the "MENU" button.
f
The "HOME" button takes you to the standard display. If you have
not changed any settings for a while, the appliance automatically
switches back to the standard display.
4.5.1 Parameter
Description
P1
Set room temperature
P2
This parameter defines the
runtime for intensive ven-
tilation. After this time has
expired, the appliance returns
to the previously applicable
fan stage.
P3
Passive cooling operating
mode
P4
Reset filter
P28 Enable fan
P80 Day
P81 Time
P82 Level of lighting
P83 Mode of backlighting
P84 Illumination duration
P85 Lower standard display
In order to set the parameter, you must first make it editable by
pressing the "OK" button. Then you can change the value with
the Touch-Wheel. If you do not press the "OK" button to make the
parameter editable, activating the Touch-Wheel causes the next
parameter to be displayed.
Press the "OK" button to save the set value for a parameter. If you
do not confirm the parameter change with the "OK" button, your
change will be lost.
„P1 : Set room temperature
Use this parameter to set the outside temperature from which pas-
sive cooling ensures that outdoor air bypasses the heat exchanger
and flows directly into the building.
Unit Min. Max. Options
°C
5
28
min 1
240
0 | 1 | 2 | 3
1 | 0
On  | OFF
1 - 7
00:00 23:59
2
10
Auto | On  | OFF
s
1
500
OFF | Time  | Set room
temperature  | Extract
air temp.  | Extract air
humidity
LWZ 130  |
33

Werbung