Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha CL1 Referenzhandbuch Seite 254

Digital mixing console
Vorschau ausblenden Andere Handbücher für CL1:
Inhaltsverzeichnis

Werbung

4.8 FUNCTION CALL – CHANNEL –
4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device number of both [Rx CH] and SUB STATUS are
matched. The data will be echoed when [PARAMETER CHANGE ECHO] is on.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
Digital mixer
GROUP ID
00111110 3E
CL-Reihe
MODEL ID
00010010 19
DATA CATEGORY 00000000 00
OTHER DATA
FUNCTION NAME 01000011 "C"
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
(ASCII CODE)
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
Source Channel Number H *1)
DATA
0sssssss sh
Source Channel Number L *1)
0sssssss sl
Destination Channel Number H *1)
0ddddddd dh
Destination Channel Number L *1)
0ddddddd dl
End of exclusive
EOX
11110111 F7
4.8.2 Module Name
Module Name
Pair On (with Copy)
"PAIRONCP"
Pair On (with Reset Both)
"PAIRONRS"
Pair Off
"PAIROFF_"
*1)
0 :CH1
- 71:CH72
256 :MIX 1
- 279:MIX 24
512 :MATRIX 1 - 519: MATRIX 8
4.9 LEVEL METER DATA
4.9.1 Format (PARAMETER CHANGE)
When transmission is enabled by receiving Request for Level Meter, the corresponding metering data will be sent in every 50
millisecond for 10 seconds. If metering information is expected to be continuously sent, Request is needed to be sent in at least every
10 seconds.
Receive
The data will be echoed when [PARAMETER CHANGE ECHO] is ON.
Transmission
When transmission is enabled by receiving Request, the corresponding metering data will be sent in constant interval for a given
period of time (The interval and time will vary depending on devices). When rebooted or port setting is changed, the transmission
will be disabled.
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
CL-Reihe
MODEL ID
00010010 19
REMOTE LEVEL METER
DATA CATEGORY 00100001 21
DATA
0mmmmmmm mm
ADDRESS UL
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
0ddddddd dd
Data1
:
:
End of exclusive
EOX
11110111 F7
4.9.2 Format (PARAMETER REQUEST)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device number of both [Rx CH] and SUB STATUS are
matched. The data will be echoed when [PARAMETER CHANGE ECHO] is on. the corresponding metering data will be sent via
[Rx CH] in constant interval for a given period of time (The interval and time will vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be immediately stopped [disabled].
Transmission
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0011nnnn 3n
Digital mixer
GROUP ID
00111110 3E
CL-Reihe
MODEL ID
00010010 19
REMOTE LEVEL METER
DATA CATEGORY 00100001 21
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
0ccccccc cl
Count L
End of exclusive
EOX
11110111 F7
254
Anhang
– Referenzhandbuch

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cl5Cl3

Inhaltsverzeichnis