4. OPERATING ELEMENTS AND CONNECTIONS

1
Microphone input MIC
Input jack for connecting a microphones via a balanced XLR cable. For
condenser microphones, a 48 V phantom power can be activated with
the +48V switch.
2
LINE input
Balanced 6.3 mm jack for connecting audio units with line level.
3
Selector switch for the high pass filter
• Switch engaged: filter on
• Switch disengaged: filter off
4
Gain control
For adjusting the input amplification of the microphone and line input.
5
LINE input
Balanced 6.3 mm jacks for connecting audio units with line level. When
connecting a mono device, only use the upper jack L/MONO.
6
Tone control HIGH
Controls the high range: ±15 dB at 12 kHz.
7
Tone control MID
Controls the midrange: ±15 dB at 250 Hz - 6 kHz.
8
Control FREQ
Control for adjusting the filter frequency for the equalizer in the
midrange (250 Hz - 6 kHz).
9
Tone control LOW
Controls the low range: ±15 dB at 80 Hz.
10
Controls AUX 1 PRE und AUX 2 POST
Control the signal sent to the outputs AUX SEND 1 and 2.
• The signal for the output AUX SEND 1 is pre-fader and can be used
for a monitor or zone system.
• The signal for the output AUX SEND 2 is post-fader and can be
used for effectors.
11
Control PAN
• Mono channels: places the mono signal in the stereo sound. The
signal level remains constant.
• Stereo channels: balance control for the stereo signal.
12
Peak LED
Lights when the corresponding channel is overloaded. If it lights
permanently, reduce the channel level with the gain control or the tone
controls.
13
Selector switch PFL
When engaged, the channel signal is switched to the PFL bus. The
signal level is indicated by the LED level meter and can be monitored
via headphones or speakers connected to the monitor output.