Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8

Installation

A
Lock to be opened with supplied special key.
B1
The corner details can be lifted and are prepared with knockouts
used for sealing or hiding cable entry. The position of them should
however remain (due to mechanical differences). They are num-
B2
bered like this:
81284 (B1) = Lower left corner.
81285 (B2) = Upper left corner.
C
The box is fastened on the wall with four screws. Brackets are
supplied to allow for using glands M12x1.5 (these are not included).
If glands shall be used the default washers have to be removed.
D
The cables can either be safely mounted (cable goes over the
edge) - or via knockouts in the same edge. Prepared with fixing
details for securing the cables with cable ties.
E
Power in: Terminal block nos. 1 and 2. 10-40V DC or 8-28V AC.
F
Opening relay. Voltage free contacts. Maximum load 2 A.
G
Relay for Warning, Monostable Alarm by-pass, Alert or Duress.
Software controlled. When Alert is selected also the tamper switch
will activate the relay.
H
RS485 connection for system communication Com A & Com B to
USB-RIF/2 (Entro Lite), next DC800 or SR34i (Entro).
I
Input for door monitor contact. Indicates open or closed door.
J
Remote opening input. For connection of an exit request button
(push to make).
C
C
B2
B2
81285
81285
D
D
A
A
81284
81284
B1
B1
E
E
F
F
G
G
H
H
I
I
J
J
K
K
ENGLISH
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
A
0
0
B
B
P
P
R
R
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
A
0
0
B
B
Q
Q
K
Connection of card reader/keypad. Maximum load 300 mA.
Maximum distance for BC-Link readers are 100 m (dependant on
cabling). Maximum distance for Clock & Data readers, e.g. proxim-
ity reader are 50 m.
L
Jumper for output voltage selection to reader/keypad +5V or Vin=
incoming supply.
Warning! Make sure the setting is correct, otherwise readers will be
damaged.
Default: +5V.
Jumper for interface selection - Clock & Data, BC-Link or
M
Wiegand (26bit, 32bit or 8bit PIN code).
Default: BC-Link.
N
Jumper for system configuration - Stand-Alone, Entro Lite or
Entro.
Default: Stand-Alone.
O
Jumper for address selection 1-8 for Entro Lite or Entro.
Default: Address 1.
Tamper switch. Gives warning if the DC800 controller's lid is
P
opened. Note! Will also activate the relay in item G when this is
setup as Alert.
Q
Keypad 0-9 plus A & B to programme the DC800.
R
LEDs (red, yellow & green) that together with the buzzer indicates
the different steps in the programming sequence. When the
DC800 is in idle mode, the green LED will flash approx. every 5
second to indicate that the DC800 powered.
C
C
L