Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Steinbach 00-40917 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
Function
The new T-serial swimming pool pump is the high-tech version of the
normal swimming pool pump. The new one has an included timer.
By adjusting the desired time (2,4,6,10,12,16 or 24 hours), the pump
will operate from this point in time for the adjusted time and stand
still for the rest of the 24 hours.
Within 24 hours, the filter run time can be adjusted only once. Ad-
justing several intervals within 24 hours is not possible.
The timer has a rechargeable battery
2032) included to save the settings in the case of a electrical power
outrage. If there will be an electrical power outrage the pump will
start automatically at the next day, if the electrical power is back.
The remaining time of the filter cycle is showed on the LED of the
pump.
Description (Illustration 1)
1 drain cap
2 pump body
3 screw M88*3r
4 inlet connector
5 outlet connector
6 timer
7 body cover
8 fix hole
9 base plate

Technical Specifications

For technical specifications please refer tot he type plate oft he filter
pump.
Before replacing the battery the pump must always be separat-
ed by pulling out the mains plug from the mains!
Commissioning of the timer / battery
change
Use a screwdriver to tighten the
Open the cover
Gently press your finger to the side of the battery, this pops out
freely. Change the battery (lithium button cell 3V CR
tion 4)
WARNING-INITIAL:
The already built-in battery has a protective part (plastic strips) to
prevent premature discharge of the battery to. Before commissioning
it must be unlocked. If it can not be unlocked, the timer still works
flawlessly. However, be saved filter run times will be deleted in the
event of a power outage.
(Illustration 4A, 4B)
Close the cover.
Use a screwdriver to tighten the cap back on.
Timer Settings
Example for 6 hours filter time:
Switch on the pump, if the indication light isn´t red. (Illustration 7)
Press the timer, until the LED "6" turns red. (Illustration 8)
Press the ON/OFF button to start the pump, then the 6H interval will
start.
From this point the filter pump runs for 6 hours non-stop. For
example: If you press the ON/OFF button in this example by 12
o'clock, then the filtration sys-tem is running until 18 o'clock. The
next day at 12 o'clock, it will start again
Initial start with external filter control
If the operation is not required with the included switch, proceed as
follows. Make sure that the battery is fully functional in the timer.
Then adjust clock for 24 hours continuous operation. Now, an exter-
Page 4 of 28
(lithium button cell 3V CR
screws.(Illustration 2)
2032). (Illustra-
(Illustration 6)
.
(Illustration 9)
nal timer-clock can be preceded and set arbitrarily (or several inputs
and turn-off times are now
possible).
Safety
Specified Conditions of Use
 This pump must not be used to supply drinking water or for pump-
ing foodstuff.
 Explosive, flammable, aggressive fluids or substances detrimental
to health as well as salt water must not be pumped
 This pump is not suitable for commercial or industrial use.
 Modification of the pump or use of parts not approved by the man-
ufacturer is not permitted.
 Any other used is not as specified. The manufacturer assumes no
liability for damage caused by un-specified use.
General Safety Instructions
Children, juveniles and persons not familiar with the instructions are
not permitted to operate the pump. When used as domestic water
supply all applicable local regulations pertaining to water supply and
waste water dispos-al, plus DIN 1988 (where applicable) have to be
observed. The following residual risks do principally exist when op-
erating pumps and pressure vessels and con not be fully eliminated
– even by employing safety devices
Hazard gererated by ambient condition!
 Do not expose to rain. Do not operate in damp or wet environment.
 Do not use the pump in hazardous locations or near inflammable
liquids and gases!
Danger! Risk of electric shock!
 Do not direct water jet directly against the pump or other electrical
parts! Risk of fatal electric shock!
 Do not touch the plug with wet hands! To unplug always pull on
the plug, not the power cable.
 The earthed outlet or the plug connection to an extension cable
must be located in an area safe against flood-ing.
 Use only extension cables of sufficient lead cross section. Comple-
tely unroll cable reels.
 Do not buckle, squeeze, drag or drive over power cable and ex-
tension cables; protect from sharp edges.
 Place extension cable so that it can not get into the fluid to be
pumped.
 If the supply cord is damaged, it must be replaced by the manufac-
ture or its service agent or a similarly qualified person in order to
avoid a hazard.
 Unplug: prior to all servicing.
 This appliance is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervi-
sion or instruction con-cerning use of the appliance by a person re-
sponsible for their safety.
 Children should be supervised to ensure that they do not play with
the appliance.
Danger by pump failures
 If you notice transport damage while unpacking, notify your suppli-
er immediately. Do not operate the pump!
 Before each use check the pump, especially the power cable and
plug for possible damage. Risk of fatal electric shock!
 A damaged pump must be workmanlike repaired before it can be
used again.
 Do not attempt to repair the pump yourself! Only trained specialists
are permitted to service or repair pumps or pressure vessels.
General
The purpose of these instruction is to ensure the correct installation
and to have the best performance of your pump.
The pump is designed for using clean water, up to a maximum tem-
perature of 35°C. All used materials are of excellent quality and are
.
Filterpumpen / Timer | 2013_V3