Problem
The pump is not running.
If the problem cannot be solved, contact the customer service listed on the last page.
Technical data
Model:
SPS 175-1T
Item number:
040090
Pump function principle:
self-priming
Prefilter:
available
Timer:
integrated timer
Battery for timer:
CR2032 button cell;
lithium 3V
Power supply:
220-240 V~, 50 Hz
Output:
max. 900 W
**** Emission sound level comparable to a large household appliance
Possible cause
The timer is set.
The external timer is set.
Flow rate:
Delivery head:
Pool volume (water
content):
Water temperature:
Connection diameter:
Safety class:
Insulation class:
Sound pressure level ****:<70 dB(A)
Remedy
Press the timer button. The running time
can be set when the pump is switched off.
Turn on the pump.
Check the running times on the external
timer.
max. 20,000 l/h (24.2
GPM)
max. 15.0 m (49 ft.)
max. 61,000 l (10,000 gal)
max. 35 °C (95 °F)
Ø 50 mm (2 in)
IPX5
F
25