Installing the mounting bracket
Figure 2: KVM s2-1602 Horizontal Installation
Rack Loading
Overloading or uneven loading of racks may result in shelf or rack
failure, causing damage to equipment and possible personal injury.
Stabilize racks in a permanent location before loading begins. Mount
components beginning at the bottom of the rack, then work to the top.
Do not exceed your rack load rating.

3.2.1 Installing the 1U switch mounting bracket

Remove the first two screws on each side.
Line up the holes in the "long side" of the kit's side brackets with the screw
holes in the switch.
With a Phillips screwdriver, fasten the mounting brackets to the switch using
two screws on each side.
Attach four cage nuts or clip nuts to the rack mounting flange of the rack cabi-
net so that the nut is positioned on the inside of the rack.
Nuts are not included with the rack mount kit.
Mount the switch assembly to the rack cabinet by matching the holes in the
"short side" of each bracket to an appropriate set of matching holes on your
rack cabinet. Next, insert the combination hex head screws through the slots
in the bracket and the holes in the mounting rail, then into the cage nuts or clip
nuts.
8
Installation
590-334-609F