1.3 Measuring positions

To define the various measuring positions during the alignment procedure we use
the analogy of a clock as viewed from behind the Movable machine. The position
with the measuring units in an upright position is defined as 12 o'clock while 90°
left or right is defined as 9 and 3 o'clock.
Fig. 4. The analogy of a clock
A
Measuring unit marked S on the stationary machine
B
Measuring unit marked M on the movable machine
C
Movable machine