3. Instructions for use

3.1 Attach the measuring units

a) Use the fixtures to attach the measuring units to the shafts. Make sure that the unit
marked M is attached to the Movable machine and the unit marked S to the Stationary
machine (see section 1.2).
For shaft with a diameter larger than 150 mm, an accessory extension chain
(TMEA C2) is required.
Fig. 8. Attachment of mechanical fixture with chain
If it is not possible to attach the fixtures directly to the shafts (e.g. in case of space
problems) the fixtures can be attached to the coupling.
b) Connect the measuring units to the display unit. Make sure that the marking on the
cables corresponds to the marking of the ports in the display unit (see fig 6)

3.2 Switch on

Switch on the display unit by pressing the ON/OFF button (see fig. 6).
You will now be prompted to enter the machine dimensions as per section 3.4.

3.3 Aim the laser lines

a) Put the two measuring units in the 12 o'clock position with the help of the spirit levels
(fig. 4 & fig.7).
b) Aim the laser lines so that they hit in the centre of the target of the opposite
measuring unit (fig. 9).