Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Checks; Faults And Possible Solutions; Possible Cause - Enofrigo Miami Mini Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43

16. MAINTENANCE AND CHECKS

Before carrying out any maintenance operation, turn the main switch off and unplug the unit from the
socket interlocked with switch..
Once a day
• • Check that the power supply cable is in perfect condition; if not, replace it with another one of the same
type.

17. FAULTS AND POSSIBLE SOLUTIONS

For troubleshooting and related repairs, refer to the table below.
FAULT
The refrigeration
system does
Not start.
The machine
temperature is
Not colde nough.
The machine
temperature is too
cold.
Ice on the innner
backside
26

POSSIBLE CAUSE

Themachine is un plugged.
From the current socket.
The power supplì cable is damaged or
interrupted.
The mains bipolar switch is off.
Power failure on controls.
There is a current interruption on the
controls.
The compressor does not work.
The thermoregulator is not correctly set.
The machine is installed near a heat
source.
The machine ispositione dless than 15cm
away from surrounding obstacles.
The air circulation via the ventilation
apertures is obstructed.
There is an interruption in the refrigeration
circuitor there is no gas.
The thermoregulat or is not set to the
correct position.
The door has been kept open for a long
time or the inside temperature is too low.
POSSIBLE SOLUTION
Plug in correctly.
Check the condition of the cable.If
necessary contact a qualified technician
to replace it with another one of the
same type.
Turn the mains bipolar switch on.
Check the condition of the controls If
necessary,contact a qualified technician
to restore the current.
Ad just the thermoregulator as come
shown in chapter n°13.
Check the condition of the.
compressor. If necessari contact a
qualified technician to replace it with
another one of the same type.
Ad just the thermoregulator as come
shown in chapter n°13.
Move the machine a way from the heat
source as described in chapter n°12.
Move the machine away from the
surrounding obstacles,as shown in
Chapter12.
Free the ventilation apertures.
Contact a qualified technician to check
that the gas expansion temperature.
Ad just the thermoregulator as come
shown in chapter n°13.
. Check the hermetic lock of the door.
Increase
automatic
manual defrosting.
Set thermoregulator as indicated in
defrosting.
Set
Rev.01 – 11/11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis