8. Do not install glass shelves on models line 1 - 2 - 10 as they may compromise the working temperatures.
9. For the models provided with accessories, fit all the accessories as shown in the following figures:
TUBOLARS
MOULDED HOUSINGS
SHELVES

13.1 Control panel

The control panel is located on the base and contains the following commands:
Electronic thermoregulator: permits regulation of the machine temperature, switch-on
and switch-off of the refrigerating system and lighting (for use of the thermoregulator, see
instructions below).
You are advised to switch the light on only when the unit is actually being used.
13.2 Editing
Edit main compartment temperature set-point
1. Push Set button to display stored value.
2. Edit the value pressing ▲ e ▼.
3. Confirm new value by press Set.
Manual defrosting
1. Keep pushing DEF ▼ button more than 5 seconds.,
Defrost duration (measured in minutes)
1. Keep pushing PRG button more than 5 seconds.,
2. Search parameter F4 by press ▲ e ▼.
3. Push Set button to display stored value.
4. Edit the value pressing ▲ e ▼.
5. Push Set button.
6. Confirm new value by press Prg more than 5 seconds.
Reset electronic control to the factory setting in case of trouble.
1. Unplug the power cord.
2. Keep pushing Prg button.
3. While pushing Prg, plug the power cord and wait a few
seconds till the display shows code bn0.
4. Search parameter bnX by press ▲ e ▼, where X reports
the model as shown in the following table.
5. Push Set button.
The termoregulator instructions are inside the booklet about the usage of it.