health regulations. In particular:
• Avoid positioning the machine near sources of heat (radiators, ovens, burners etc.) or
draughts. If this is not possible, the following minimum distances must be observed:
50 cm from coal or oil cookers and 50 cm from electric/gas cookers.
• To prevent inefficient refrigeration, avoid exposing the machine to direct sunlight.
• To ensure that the refrigeration works properly, leave a 15 cm gap around the entire
machine.
Carefully unpack the machine, removing the main cardboard box and then all the
packaging protection materials..
Once you have removed the packaging, check that the machine is in perfect condition and
notify the manufacturer or authorised dealer of any damage found within 48 hours from
receipt of the goods.
For installation of the machine, take account of the data given on the identification plate
and the overall dimensions (see chapter n° 5 and n° 6).
When the machine is installed at over 900 (nine-hundred) metres above sea level, each
double-glazing unit has to be fitted with a compensating valve.
A free space of approximately 50 cm must be left around the machine for operation and
maintenance.
You are strictly forbidden to use the machine in places where there is the dangerof explosion or fire due
to the presence or development of dust, gas or explosive or flammable mixtures.
The packaging materials must be disposed of in compliance with current local regulations concerning
industrial and special waste.

13. START-UP, OPERATION AND ADJUSTMENT

To obtain the best performance from the refrigeration unit, the following conditions must
obtain:
• Ambient temperature = 25 ° °C
• Relative humidity R.H. = 60%
• Climate class according to UNI EN 441 = 3S
You are advised to wait at least two hours before using the system in order to ensure that the
refrigeration circuit is operating efficiently..
Before starting the machine, follow the instructions below:
1. Check that the system and the electrical connections comply with the current localregulations.
2. Check that the machine voltage specified in the identification plate corresponds to the line voltage at the
socket. If not, suspend electrical connection and call the manufacturer or authorised dealer.
3. Check correct earthing of the machine and availability of a mains bipolar switch with differential.
4. If the power supply socket and plug are not of the same type, have the socket replaced by a qualified
technician. Do not use extensions or multiple adapters. The power supply cable and plug must be easily
accessible after installation. If they show signs of wear or damage, they must be immediately replaced by a
qualified technician.
5. Check that the compressor protection grille is properly fixed.
6. Ensure that the feet are all adjusted to the same height..
7 Fix the handle to the door frame using the screws provided.