Keeping it clean:
1 IMPORTANT: the steam nozzle should be cleaned after
each use in order to avoid build up of milk deposits that
are very diffi cult to clean. Cleaning is made easy as can
be seen in the DESCRIPTION OF PARTS. The outer part of
nozzle can be removed by pulling downward.
The outside of the steam pipe can be cleaned with a damp
cloth.
The steam jet is cleaned by running a shot of steam
through it.
The hole in the steam nozzle must be kept open. A needle
may be used.
Pay attention as the Turbo-Frother
steam nozzle could be hot!
2 Clean fi lter holder and fi lter in warm water after use.
3 Wipe body of machine with a damp cloth as required.
N.B.: The machine has a sensitive keypad activated by simply
touching or brushing the sensor areas (keys 2, 3, 4, 6).
Turn off the machine when cleaning in order to avoid
activating it by mistake.
4 Remove basin and grid (12, 23) and rinse with water. Do
not use abrasive substances.
5 Clean the seal (15) inside of the brewing head (14) and
keep it clean.
6 The shower disc (17) should be unscrewed and cleaned
periodically depending on frequency of use.
7 If the machine is not used for a long period of time,
completely discharge the water from the boiler by turning
the steam knob (25) clockwise. Press steam switch (5)
Air intake to be kept clean and
free from residues.
• 19 •
until completely discharged. Close the steam knob (25)
by turning it counterclockwise and switch off the machine.
Never run the pump without water.
8 NOTE: It is very normal for an espresso machine to emit
steam and drip occasionally as the water pressure changes
during use.
Be certain to empty drip tray (12) as required.
Descaling
Limescale normally builds up with the use of the appliance.
The machine needs descaling every 1-2 months (if used)
and/or whenever a reduction in water fl ow is noticed. Use
the GAGGIA descaling solution only.
NOTE: In case of confl ict, priority must be given to what is
indicated in the operation and maintenance manual over
the instructions provided on separately sold accessories
and materials.
N.B.: Use the GAGGIA descaling
solution only. Its formula has been
designed to ensure better machine
performance and operation for its
whole operating life. If correctly
used, it also avoids alterations in
the brewed product. The descal-
ing solution is to be disposed of
according to the manufacturer's
instructions and/or regulations in
force in the country of use.
N.B.: Never drink the descaling solution or any products
dispensed until the cycle has fi nished. Never use vinegar
as a descaling solution.
1 Insert the fi lter holder into the brew unit from the bottom
(14) and turn it from left to right until it locks into place.
2 Remove and empty the water tank.
3 (Fig.02) - Pour HALF the content of the GAGGIA
concentrated descaling solution into the water tank, and
then fi ll the tank with fresh drinking water up to the MAX
level.
4 Remove the Pannarello (or Cappuccinatore) installed on
the steam wand, if any.