Safety information

Before commissioning, please note:
Please read through these instructions carefully. They contain essential information for the installation, use and safety of the
equipment.
Qualified personnel and equipment handling
WARNING
Risk of injury due to dangerous electrical voltages and moving mechanical parts.
Only appropriately qualified personnel may work on or in the vicinity of the equipment. Personnel must be thoroughly
familiar with all the warnings, notices, and functions of the ATD400K controller described in these operating instructions.
In the context of the operating instructions and warning notices, a qualified person is a person who is familiar with
assembling, installing, commissioning, and operating the product, and who has the relevant qualifications, such as:
● Training, instruction or authorization to switch on and off electric circuits and devices / systems in compliance with
safety engineering standards.
● Training or instructions in the maintenance and use of appropriate safety equipment in compliance with safety
engineering standards.
● First aid training.
The successful and safe operation of the equipment is dependent on proper transportation, storage, installation, and
assembly, as well as on careful operation and maintenance. Before commissioning, all electrical connections must be
inspected to ensure that all contacts are secure.
WARNING
Risk of injury due to dangerous electrical voltages and moving mechanical parts.
Disconnect the gate drive by unplugging the power plug from the power supply before starting work on the gate drive.
WARNING
Risk of injury and damage to property due to excessive gate closing force.
Exceeding the static closing force may lead to personal injuries, damage to the gate drive and to mechanical components
of the gate.
The maximum static closing force must not exceed 150 N! With the reversing device switched off, the maximum static
closing force must not exceed 70 N!
Modifications to the gate drive are not permissible
CAUTION
Loss of liability for defects and damage to property
Modifying the gate drive leads to the loss of liability for defects and claims and the correct function of the gate drive is no
longer ensured.
Note the following rules:
● Do not make perform any modification of the gate drive (motor, controller, power supply).
● Do not carry out a permanent connection as this does not ensure a proper and required necessary disconection from
the mains.
● Do not remove the protective Schuko-type socket under any circumstances (e.g. by truncating).
● The power supply cable cannot be replaced. Scrap the power supply if the supply cable is damaged.
Cold room gate drive ATD400K
A2B00101049-01, 08/2012
25