Note
AT system series power supplies are fitted with a molded safety plug in line with VDE. The plug forms part of the safety
chain of the AT system in the form of the "emergency stop" function. Permanently connected power supplies, including those
with a separate "emergency stop" switch, represent a modification of the certified device, and are not permissible.
Sidoor gate drives are "Equipment" and not "electrical installations in the proper sense". A type of equipment is subject to
other tests and guidelines than electrical equipment. Therefore - e.g. in the case of a possible insulation measurement of an
electrical installation carried out with a DC voltage of 500 V - the equipment (gate drive) must be disconnected from the
network, otherwise the built-in protective circuit of the power supply may be destroyed. A permanent connection must not be
made for the reasons stated, because it cannot be ensured that the device can be properly disconnected from the mains
when required.
2
Introduction
Cold room gate drive ATD400K
The cold room gate drive ATD400K is an "intelligent" gate drive which drives cold room gates. The power-operated
protective device fulfills the requirements of protection level C according to Category 2 / Performance Level d of
DIN EN 12453:2000 5.5.1, and those of Category 2 / Performance Level d of DIN EN ISO 13849-1:2008.
The toothed belt passes over a deflector pulley, and can be fitted with two gate clutch holders. This enables it to drive both
single-sided and centrally-opening cold room gates.
The ATD400K can currently be used with the following components:
Component
Control unit
Motor M3
Motor M4
Transformers
Emergency power
module
supports the function of the light barrier
1
supports the function of the gate interlocking
2
Operation of the gate drive does not require limit switches. The gate width and the OPEN and CLOSED positions are
determined automatically. A 7-segment display (H401) on the controller indicates the current operating states.
Operating instructions
These operating instructions are also installation instructions within the meaning of the Machinery Directive (2006/42/EC).
These operating instructions are valid for devices from firmware versions 1.02 and 2.02.
Note
The illustrations in the instructions refer to Sidoor User Software version 1.11 and ATD400K versions 1.02 and 2.02. The
illustrations for other versions may differ slightly.
26
Version
Controller for ATD400K (basic type)
Controller for ATD400K (type 1)
30 V motor, pinion right, for gates up to 180 kg
30 V motor, pinion left, for gates up to 180 kg
30 V motor, pinion right, for gates up to 400 kg
30 V motor, pinion left, for gates up to 400 kg
Mains transformer
Emergency power module with connecting cable
1
2
Order No.
6FB1141-1AT10-3KU2
6FB1141-1AT11-3KU2
6FB1103-0AT11-4MB0
6FB1103-0AT10-4MB0
6FB1103-0AT11-3MC0
6FB1103-0AT10-3MC0
6FB1112-0AT20-2TR0
6FB1115-0AT10-4CP0
Cold room gate drive ATD400K
A2B00101049-01, 08/2012