Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The Inverter - SMA SUNNY TRIPOWER STORAGE 60 Installationsanleitung

Vorschau ausblenden Andere Handbücher für SUNNY TRIPOWER STORAGE 60:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
2  Installation
INFORMATION
Use of the wall mounting bracket delivered with the
inverter is mandatory. Warranty claims will expire if
the inverter is operated without the wall mounting
bracket. It is strongly recommended to use all six
mounting holes (see figure 2.10).
Mounting of the wall mounting bracket:
• Mount the wall mounting bracket in the designated
area.
• Use screws and wall plugs that can safely carry the
weight of the inverter.
• Ensure that the wall mounting bracket is correctly
aligned.
• When installing one or several inverters, observe the
safety clearances to ensure sufficient airflow.
Clearances are specified in figure 2.8 and on the wall
mounting bracket label.
• Mounting multiple inverters side by side in a single row
is recommended. Contact the supplier for guidelines
when mounting inverters in more than one row.
• Ensure adequate clearance at the front, for safe
installation and service access to the inverter.
Figure 2.10 Mounting of the wall mounting bracket

2.3 Mounting the Inverter

When handling the inverter observe the local health and
safety regulations.
24
STPS60-IA-xx-12
Procedure:
1. Attach M12 lifting bolts and matching nuts to the
inverter (not included in the scope of delivery).
2. Lift the inverter.
Figure 2.11 Attaching the lifting bolts and lifting the inverter
3. Locate the slots on the side of the wall mounting
bracket.
4. On the inverter, position the side screws against the
wall mounting bracket slots. Push the inverter so the
side screws slide into the two lower slots and the two
upper slots.
Figure 2.12 Hooking the inverter into the wall mounting bracket
SMA Solar Technology AG
Installation Manual

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis