6-1-3. Communication Format

Communication data output format
[Example]
Channel 0
Channel 1
Output data
Output data
v Header:
5 bytes (this differs depending on communication mode)
Byte 1 : Leading character ................. unit number
Byte 2 : 2nd character ........................ channel number 0 to F
Byte 3 : 3rd character ........ mode Current value mode
Byte 4 : 4th character ............................................... unit M (mm)
Byte 5 : 5th character comparator
judgment value ................. Upper limit NG
28
(E)
Channel n
Delimiter
Output data
0 to F
: N
Maximum value mode : A
Minimum value mode
: I
Peak-to-peak value mode : P
I (inch)
: U
Within range
: G
Lower limit NG
: L
When an alarm has occurred : E
xNumerical value:
Fixed at 8 bytes : + or _ sign followed by the data
(including decimal point)
[Example 1] For a resolution of 0.1 µm
: "_99.9999" to "+99.9999"
[Example 2] For a resolution of 10 µm
: "_9999.99" to "+9999.99"
[Example 3] In the event of an overflow, the count continues
but the leading character changes to "F."
"_99.9999" → "_F0.0000" → "_F0.0001"
[Example 4] When an alarm has occurred, "Error" appears
: (" "," "," "E","r","r","o","r"," ")
sData separate character:
1 byte " " (space) or 2 bytes "
Select using RS-232C command (factory setting: space).
zDelimiter:
C R
" + "
L F
2 bytes "
" or 1 byte "
Select using communication setting switch No. 2. on main unit.
OFF : "
C R
" + "
L F
" (factory setting)
C R
ON : "
"
C R
" + "
L F
"
C R
"
MG10-P1 / MG10-P2