Herunterladen Inhalt Inhalt Diese Seite drucken

Sony MG10-P1 Bedienungsanleitung Seite 53

Multi-schnittstellengerat/hauptmodu
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1 POWER lamp
Lights green when the power is on and the unit is ready for
operation.
2 Alarm lamp
Lights red when any counter module of the unit enters the alarm
status.
3 HOLD lamp
Lights orange when the hold function (in which current value
output data is latched or the peak value data updating is stopped)
is activated in any counter module of the unit.
4 Unit number setting switch
Sets the unit number to a number from 0 to F.
5 RS-232C communication setting switch
Sets the RS-232C communication specifications.
6 I/O connector
Connects the I/O connector of a PLC or other device and
controls it.
7 Power input socket
The external power supply (DC +12 V to 24 V) is connected
here.
MG10-P1 / MG10-P2
8 RS-232C connector
Connects the unit to a computer or PLC host unit.
The connector at the end of the RS-232C cable (DZ252) sold
separately is connected here.
9 LINK IN connector
When using the link connection for the units, the link cable
(LZ61) is used to connect this connector with the LINK OUT
connector of a higher order unit's main module.
0 LINK OUT connector
When using the link connection for the units, the link cable
(LZ61) is used to connect this connector with the LINK IN
connector of a lower order unit's main module.
qa Counter module connector
This is connected to the counter module.
qs I/F module connector
This is connected to the I/F module.
qd Slide locks
Secures a module which has been connected.
qf DIN rail anchoring lever
Secures the main unit to the DIN rails.
5
(E)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mg10-p2

Inhaltsverzeichnis