Herunterladen Inhalt Inhalt Diese Seite drucken

Start; Go/No Go Judgment (Comparator) - Sony MG10-P1 Bedienungsanleitung

Multi-schnittstellengerat/hauptmodu
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4-2-5. Start

This function starts updating the peak value as soon as an input is
supplied.
Changes in measured values in each mode when an
input is supplied
Current value
Remains unchanged
Maximum value
Current value prevailing when the input
was supplied is set
Minimum value
Current value prevailing when the input
was supplied is set
Peak-to-peak value
Value obtained by subtracting the minimum
value (zero) from the maximum value when
the input was supplied is set
MG10-P1 / MG10-P2

4-2-6. Go/No GO Judgment (Comparator)

This function judges "go" or "no go" for the measured values in
the measuring mode which is set.
The Go/No GO judgment results are added to the RS-232C data, or
BCD data of MG30-B (sold separately), and output.
The comparator values set the upper and lower limits. Up to four
sets of comparator values can be set, and the set of values used can
be switched partway through the measurement.
Measured value
Measured value > upper limit
Measured value = upper limit
Lower limit < measured value < upper limit GO
Measured value = lower limit
Measured value < lower limit
Judgment
RS-232C
judgment
output
Upper limit NG
U
GO
G
G
GO
G
Lower limit NG
L
15
(E)