Herunterladen Inhalt Inhalt Diese Seite drucken

SATA adam 2 Betriebsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für adam 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

<< Operating Instructions SATA adam 2 >>
<< Operating Instructions SATA adam 2 >>
EN
• The SATA adam 2 / SATA adam 2 mini / SATA adam 2 display must not
be brought along with or used on a paint spray in explosive areas classi-
fied as Ex-Zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
The electronic pressure measuring device has been submitted to a de-
sign examination and is developed, constructed and manufactured in
accordance with the EU directive 94/9 EU. It was classified to II 2 G Ex
ia IIC T4 FM Global IS CL I, ZN 1, AEx ia IIC T4 IS CL I, DIV 1, GP A,
B, C&D, T4 and may be used and stored in the explosive zones 1 and 2
up to 60°C ambient temperature. Inspection authority: KEMA 05 ATEX
1090 X.
Ex-sign
Equipment category
IECEx label: IECEx KEM 09.0075
The following applications and operations lead to the loss of the
explosion protection and are, therefore, prohibited:
• Battery replacement in explosive areas!
• Installation of a battery other than CR 2032, RENATA (SATA Art. No.
160739)!
VII.4
Warning! Risk of explosion!
II 2 G Ex ia IIC T4
II
2
Device category
Gas category
Warning! Risk of explosion!
G
Ex
Type of ignition protection
ia
IIC
T4
Equipment category
Temperature
classification

Werbung