OTD
x
TDIS
x*
PDIS
x*
CDIS
x*
SDIS
x*
DDIS
x*
ODB
x
x
x
INIT
x*
x*
x*
FLL
x*
x*
x*
STAB
x*
x*
x*
tDTO
x*
x*
x*
tFLL
x*
x*
x*
tSTB
x*
x*
x*
OBST
s*
RESE
x
x
x
UNIT
x
x
x
Legend
x
Appropriate channel is available.
x*
Appropriate channel is available subject to the associated option being enabled.
s*
System-specific channel is only available if the associated option has been enabled.

Appropriate channel is only available subject to the option "Heat metering" (OHQM) being enabled.

Appropriate channel is only available subject to the option "Heat metering" (OHQM) being disabled.
MEDT
The anti-freeze content channel (MED%) is only shown if the type of frost protection (MEDT) is not water or H-30 L/LS (MEDT 0 or 3).
Setting the anti-freeze content is only appropriate if anti-freeze is actually used in the solar circuit.
Note:
S3 and S4 are only displayed when the temperature sensors are connected (superimposed).
2.8.1 Display: Collector temperatures
COL, COL1, COL2:
Collector temperature
Display range:
-40 ... +260 °C
2.8.2 Display: Cylinder temperature
TST, TSTB,TSTT, TST1, TST2:
Cylinder temperatures
Display range:
-40... +260 °C
2.8.3 Display sensor 3 and sensor 4
S3, S4:
Sensor temperatures
Display range:
-40...+260 °C
2.8.4 Displaying other temperatures
TSFB, TRET, TR:
Other captured
temperatures
Display range:
-40 ... +260 °C
x
x*
x*
x*
x*
x*
x*
x*
x*
x*
x*
x*
x*
x
x
x
x
x
x
x
x
x
x
".+

323



32%!

Option, Pasteurisation
Pasteurisation temperature
Observation period
Countdown for observation period
Pasteurisation start time
Pasteurisation: Heat-up time
x
Option, Drainback
Display of the remaining time, Start con-
dition
Display of the remaining time, Filling
process
Display of the remaining stabilisation
time
Period, Start condition
Filling time of the Drainback function
Stabilisation time
Booster function (additional pump)
x
x
Reset to factory settings
x
x
Temperature unit
Shows the current collector temperature:
• COL
: Collector temperature (single collector system)
°C
• COL1 : Collector temperature 1
• COL2 : Collector temperature 2
Shows the current cylinder temperature:
• TST
: Cylinder temperature (single cylinder system)
°C
• TSTB : Lower cylinder temperature
• TSTT : Cylinder temperature, top
• TST1 : Temperature, cylinder 1
• TST2 : Temperature, cylinder 2
Shows the current temperature of the respective auxiliary sensor
(without control function).
°C
• S3
: Temperature sensor 3
• S4
: Temperature sensor 4
Note:
S3 and S4 are only displayed when the temperature sensors are
connected (superimposed).
Shows the current temperature of the respective sensor.
• TSFB : Temperature, solid fuel boiler
°C
• TRET : Heating return temperature
• TR
: Return temperature
OFF
OFF / ON
60 °C
0 ... 95 °C
01:00
0 ... 30:0 ... 24 (dd:hh)
00:00
00:00 ... 24:00
(hh:mm)
01:00
00:00 ... 24:00
(hh:mm)
OFF
OFF/ON
60 s
1 ... 100 s
5 min
1 ... 30 min
2 min
1 ... 15 min
OFF
OFF/ON
°C
°C / °F