nMN, n1MN, n2MN: Speed
control
Setting range: 30 ... 100
Factory setting: 30
Confirmation prompt

2.8 Control parameters and display channels

Channel overview
Channel Arr
1
2
3
4
COL
x
x
x
x
COL1
TST
x
TSTB
x
x
TST1
x
TSTT
x
x
x
TST2
x
TSFB
TRET
COL2
S3
x



TR



S4
n%
x
x
n1%
x
x
n2%
x
h P
x
x
h P1
x
x
h P2
x



kWh



MWh
Arr
DT O
x
x
x
DT1O
x
DT F
x
x
x
DT S
x
x
x
RIS
x
x
DT1F
x
RIS1
x
DT1S
x
S MX
x
x
x
S1MX
x
DT2O
x
DT2F
x
DT2S
x
RIS2
x
S2MX
x
EM
x
x
x
x
EM1
OCC
x
x
x
x
.*
SET
5
6
7
8
9
10
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x* Temperature, return sensor

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x* Heat amount kWh

x* Heat amount MWh
1-10
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Setting channels nMN or n1MN and n2MN, default a relative minimum speed for
connected pumps for outputs R1 and R2.
CAUTION:
When using consumers without variable speed control (e.g. valves), set the value
to 100% to disable the variable speed control.
After you have set the last parameter in the commissioning menu, the controller
will prompt you for confirmation.
Press key 3 to confirm your settings.
The controller is now ready to operate. The settings made in the commissioning
menu can be changed any time after the commissioning in the relevant parame-
ter.
Description
Temperature, collector 1
Temperature, collector 1
Temperature, cylinder 1
Temperature, cylinder 1, bottom
Temperature, cylinder 1, bottom
Temperature, cylinder 1, top
Temperature, cylinder 2, bottom
Temperature, solid fuel boiler
Temperature, heating circuit
Temperature, collector 2
Temperature sensor 3
Temperature sensor 4
Speed, relay 1
Speed, relay 1
Speed, relay 2
Hours run, relay 1
Hours run, relay 1
Hours run, relay 2
System
Start temperature differential
Start temperature differential 1
Stop temperature differential 1
Set temperature differential
Rise
Switch-OFF temperature differential
Rise 1
Set temperature differential 1
Maximum temperature, cylinder 1
Maximum temperature, cylinder 1
Start temperature differential 2
Stop temperature differential 2
Set temperature differential 2
Rise 2
Maximum temperature, cylinder 2
Emergency temperature, collector 1
Emergency temperature, collector 1
Option collector cooling, collector 1
Factory
Display/setting range
setting
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
-40 ... +260 °C
30 ... 100 %
30 ... 100 %
30 ... 100 %
1 ... 10
6 K
1,0 ... 20,0 K
6 K
1,0 ... 20,0 K
4 K
0,5 ... 19,5 K
10 K
1,5 ... 30,0 K
2 K
1 ... 20 K
4 K
0,5 ... 19,5 K
2 K
1 ... 20 K
10 K
1,5 ... 30,0 K
60°C
4 ... 95 °C
4 ... 90 °C (ANL 10)
60°C
4 ... 95 °C
6 K
1,0 ... 20,0 K
4 K
0,5 ... 19,5 K
10 K
1,5 ... 30,0 K
2 K
1 ... 20 K
60 °C
4 ... 95 °C
130 °C
80 ... 200°C
130 °C
80 ... 200°C
OFF
OFF ... ON