Herunterladen Inhalt Inhalt Diese Seite drucken

Connection For Measuring Element - ABB TTF300 Inbetriebnahmeanleitung

Temperatur-messumformer für feldmontage
Vorschau ausblenden Andere Handbücher für TTF300:
Inhaltsverzeichnis

Werbung

Fig. 5 Connection example
1 Socket (HMI interface) for LC display
4.3

Connection for measuring element

Note
The measuring element is connected via sensor connecting cable. The sensor connecting
cable is not delivered with the transmitter. It must be ordered as a separate accessory.
The model of the sensor connecting cable must correspond to the sensor model and
configuration of the transmitter.
When connecting the transmitter and measuring inset (sensor) make sure for thermocouple
sensors that the material of the sensor connecting cable corresponds to the thermocouple
model.
1. Look for the connection type for the selected measuring element in the connection diagrams.
2. Release the clamping screws for terminals 1 to 6 using the proper screwdriver. Make sure
that the screws do not fall out.
3. Insert the wires for the measuring element and sensor cable connection under the open
terminals and carefully tighten the clamping screws for the connections.
Note
The wires for the sensor connecting cable can also be soldered to the soldering tags for the
terminals in the transmitter.
CI/TTF300-X1
2 Retaining socket for the LC display
TTF300
Electrical connection
1
2
A00117