Explanation of the various modes:
C = 0
deactivated
C = 1
enables door monitoring by the "Aux Out" (9) relay contacts*
C = 2
enables triggering of the "Aux Out" (9) relay contacts for
wrong input of the user password or master code.
C = 3
enables triggering of the "Aux Out" (9) relay contacts via the
"*" button or door bell button (1).
C = 4
enables triggering of the "Aux Out" (9) relay contacts via the
sabotage contact.
C = 5
allows extended door monitoring **
C = 6
enables triggering of the "Aux Out" (9) relay contacts when the
"Lock Out" (h) relay contacts are active.
C = 7
enables triggering of the "Aux Out" (9) relay contacts via the
assigned password (see chapter 7.6)
* door monitoring
Behavioural mode: When a user code is entered, the "Lock Out" relay contacts (10) are trigge-
red. If the magnet contact is opened the "Aux Out" relay contacts (9) are triggered. If the button
attached to the "PB" (5) connection is pressed, the "Lock Out" relay contacts (10) are triggered.
** extended door monitoring
Behavioural mode: When the user code is entered, the "Lock Out" (10) and "Aux Out" (9) relay
contacts are triggered. The "green" LED (4) flashes when the magnet contact is open. If the but-
ton connected to the "PB" connection (5) is activated, the "Lock Out" and "Aux Out" (9) relay
contacts are triggered.
7.7 Setting Activation Period for
"AL OUT (-)" (2)
You can set the activation period for the alarm output "AL OUT (-)" (2). Proceed as follows:
Input example:
MMMM MMMM *56 TTT #
Explanation
TTT = 001-999 seconds
29