SECTION - 6.B
PROFESSIONAL PROGRAMMING PROCE-
DURE
(for MORX + keypads)
l The procedure maps the command keys (▲ and ▼) to output-1 and output-2 on
the decoder as follows:
– command key ▲ maps to output-1;
– command key ▼ maps to output-2.
l When executing the procedures, the two command keys (▲ and ▼) are also used
to confirm the steps of the procedure or abort the procedure.
l Professional programming mode allows you to program all the system's functions di-
rectly from the keypad: you can program any number of combinations, cancel them,
count them, cancel the entire memory and use other application-specific functions.
You can also program the decoder's outputs with the options given below.
l The decoder's outputs (1 and 2) are factory set to operate as momentaries; they
are activated when the key is pressed and deactivated as soon as it is released.
This mode can be modified with the following functions:
– TIMER mode: when an output is activated, it remains active for a set time;
– BISTABLE mode: to activate an output, press the command key one time ; to
deactivate it, press it a second time;
– SECURITY mode: the procedure sets output-1 and its command key ▲ to BI-
STABLE mode so that the user can arm/disarm a security system. Output-2 and
the ▼ key are deactivated by the function and cannot be used.
l The combination acts as the "access key" that must be programmed in accordance
with the user's needs. It is formed of up to nine digits, each in the range 0 to 9.
l Professional mode programming allows you to program a combination for each us-
er or group of users; this makes it easy to add or delete combinations from mem-
ory, as required at any time.
l Professional mode programming is only available if you have a programming
password, i.e. a special combination of 7 digits (the factory default is 0-3-3-3-3-
3-3, but this can be changed at any time). CAUTION! – If you forget this pass-
word, you will have to cancel the device's entire memory and reprogram it
from scratch - keep the programming password in a safe place!.
7 – English
PROCEDURES
6.B.1
Professional
To program a combination for command key ▲
(output-1) only (reference digit: "1")
01. Enter the programming password. – Press ▼ to confirm the password.
02. Enter the digit "1". – Press ▼ to confirm.
03. Enter the desired combination (1 to 9 digits). – Press ▼ to confirm.
04. Enter the combination again. – Press ▼ to confirm. If the procedure was suc-
cessful, the keypad will beep 3 times.
To program other combinations, repeat the procedure from the beginning.
6.B.2
Professional
To program a combination for command key ▼
(output-2) only (reference digit: "2")
01. Enter the programming password. – Press ▼ to confirm the password.
02. Enter the digit "2". – Press ▼ to confirm.
03. Enter the desired combination (1 to 9 digits). – Press ▼ to confirm.
04. Enter the combination again. – Press ▼ to confirm. If the procedure was suc-
cessful, the keypad will beep 3 times.
To program other combinations, repeat the procedure from the beginning.
6.B.3
Professional
To program a combination for both command keys: ▲
(output-1) and ▼ (output-2) (reference digits: "1-2")
01. Enter the programming password. – Press ▼ to confirm the password.
02. Enter digits "1-2". – Press ▼ to confirm.
03. Enter the desired combination (1 to 9 digits). – Press ▼ to confirm.
04. Enter the combination again. – Press ▼ to confirm. If the procedure was suc-
cessful, the keypad will beep 3 times.
To program other combinations, repeat the procedure from the beginning.