Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes; Installation Instructions; Technical Data; Symbol Description - HANSGROHE AXOR Citterio E Gebrauchsanleitung, Montageanleitung

Vorschau ausblenden Andere Handbücher für AXOR Citterio E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Shower hoses are only suitable for a connection
from the shower to the fitting. Never fit a shut-off
device between the fitting and the hose.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The premounted filter insert must be used to ensure
a normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hans-
grohe will not be held liable for this type of damage.
• Optimal functioning is only guaranteed with the com-
bination of Hansgrohe hand showers and Hansgrohe
shower hoses.
4
English

Technical Data

Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Assembly see page 32
Do not use silicone containing acetic acid!
With the excentric washer it is possible to
equalize tolerance of the drilling. (see page
34)
Dimensions (see page 31)
Flow diagram (see page 31)
Operation (see page 35)
Cleaning (see page 36) and en-
closed brochure
Spare parts (see page 37)
XXX = Colors
000 = chrome plated
820 = brushed nickel
Special accessories (order as an
extra)
cover cap set #42871XXX
Test certificate (see page 40)
max. 0,6 MPa
0,1 - 0,4 MPa
max. 60°C
max. 70°C / 4 min

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis