Instruction manual
8.7

Mechanical design

Housing components
Protective screen
Visible screen surface
Ventilation slots
Degree of protection (front)
Connection panel
Weight
Dimensions (W°xH°x°D)
8.8

Climatic conditions

Operation
Ambient temperature range
Temperature gradient
Atmospheric pressure
Transport and storage (packed)
Ambient temperature range
Temperature gradient
Atmospheric pressure
8.9

Mechanical requirements

Operation
Vibration
Shock
Packed unit
Vibration
Shock
48
ABS, TPE
Yes
Approx. 378 mm x 303 mm
In rear panel
IP20 acc. to DIN 40050
At rear, covered
Approx. 9 kg
465 mm x 444 mm x 240 mm
5 ... 40 °C
Max. 5 °C/h, no condensation
1040 ... 860 hPa
- 20 ... +60°C
Max. 5 °C/h, no condensation
1040 ... 674 hPa (0 ... 3048 m)
According to EN 60068-2-6
10 ... 58 Hz with ± 0.075 mm deflection
58 ... 500 Hz at 9.81 m/s²
According to EN 60068-2-29
50 m/s², 30 ms
According to EN 60068-2-6
5 ... 9 Hz with ± 3.5 mm deflection
9 ... 500 Hz at 9.81 m/s²
According to EN 60068-2-29
250 m/s², 6 ms (in storage packaging)