Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic ClassicController R 360 Montage- Und Installationshinweise Seite 20

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C
C
CR0020
LASSIC
ONTROLLER
CR0020
Digital/analogue inputs (B
%IW03...10
%IX0.00...07
can be configured as ...
Digital inputs (B
)
L
%IX0.08...11
%IX1.00...03
can be configured as ...
Digital inputs (B
, I
)
L
L
%IX0.12...15
can be configured as ...
Digital inputs (B
, I
)
L/H
L
%IX1.04...07
can be configured as ...
Digital inputs (B
)
L/H
%IX1.08...15
can be configured as ...
Digital inputs (B
)
L
%IX2.00...07
konfigurierbar als...
Test input
)
*
NAMUR inputs
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
20
PAGE
■ Voltage inputs
, A)
L
input voltage
resolution
precision
input resistance
input frequency
■ Current inputs
input current
resolution
precision
input resistance
input frequency
■ Digital inputs for positive sensor signals, with diagnostic capability *)
switch-on level
switch-off level
input resistance
input frequency
■ Digital inputs for positive sensor signals
switch-on level
switch-off level
input resistance
input frequency
■ Digital inputs for positive sensor signals, with diagnostic capability *)
switch-on level
switch-off level
input resistance
input frequency
■ Frequency inputs for positive sensor signals
with diagnostic capability, evaluation with integrated comparator
switch-on level
switch-off level
input resistance
input frequency
■ Digital inputs for positive/negative sensor signals, positive with diagnostic capability
switch-on level
switch-off level
input resistance
input frequency
■ Frequency inputs for positive sensor signals
with diagnostic capability, evaluation with integrated comparator
switch-on level
switch-off level
input resistance
input frequency
■ Digital inputs for positive/negative sensor signals, positive with diagnostic capability
switch-on level
switch-off level
input resistance
input frequency
■ Digital inputs for positive sensor signals, with diagnostic capability *)
switch-on level
switch-off level
input resistance
input frequency
During the test mode (e.g. programming) the "TEST" connection must be connected
to VBB
(10...32 V DC).
S
For the "RUN" mode the test input must not be connected.
input resistance
■ Digital inputs with diagnostic capability can be used as NAMUR inputs when used
with an external resistor connection.
supply voltage
We reserve the right to make technical alterations without prior notice.
Characteristics of the inputs
0...10/32 V
12 bits
± 1.0% FS
50/30 kΩ
50 Hz
0/4...20 mA
12 bits
± 1.0% FS
400 Ω
50 Hz
0.7 U
B
0.4 U
B
30 kΩ
50 Hz
0.43...0.73 U
B
0.29 U
B
3.21 kΩ
50 Hz
0.7 U
B
0.4 U
B
2.86 kΩ
50 Hz
0.43...0.73 U
B
0.29 U
B
2.86 kΩ
max. 50 kHz
0.7 U
B
0.4 U
B
3.21 kΩ
50 Hz
0.43...0.73 U
B
0.29 U
B
3.21 kΩ
max. 1 kHz
0.7 U
B
0.4 U
B
3.21 kΩ
50 Hz
0.43...0.73 U
B
0.29 U
B
3.21 kΩ
50 Hz
3.21 kΩ
5...25 V; e.g. ifm NAMUR sensors NT5001...NN5002
*
*
CR0020 / page 3
23.10.2014

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis