Electrical connection

The following can be connected for measurement signal conditioning:
S Carrier‐frequency amplifiers
S DC amplifiers
designed for strain gauge measurement systems.
5.1
Connection in a six‐wire configuration
2
3
4
5
Fig. 5.1
Connector pin assignment
With this connector pin assignment, the output voltage at the measuring
amplifier is positive when the transducer is loaded (see Fig. 4.1). The pin
assignment for the cables available as accessories can be found in Section 8
on page 15.
5.2
Connection in a four‐wire configuration
When transducers in a six‐wire configuration are connected to amplifiers in a
four‐wire configuration, the sense leads of the transducer must be connected
to the corresponding excitation voltage leads: Marking (+) with (+) and marking
(-) with (-), see Fig. 5.1. This measure also reduces the cable resistance of the
PW25P
8
Plug‐in contact 1 = measurement signal (+)
Plug‐in contact 2 = not in use
1
Plug‐in contact 3 = sense lead (+)
Plug‐in contact 4 = not in use
7
Plug‐in contact 5 = sense lead (-)
Plug‐in contact 6 = excitation voltage (-)
6
Plug‐in contact 7 = excitation voltage (+)
Plug‐in contact 8 = measurement signal (-)
A03627_02_Y00_01 HBM: public
Electrical connection