Quarz-funkssteuerung
Vorschau ausblenden Andere Handbücher für BIO Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
This is a very simple hardware lock to perform but therefore easy for other people to disable.
A second software type of lock has been fitted that is harder to operate but extremely safe since a remote
control authorized (see - enable - disable 2nd lock) or via BUPC must be used as an unlocking key.
REGULATIONS AND SETTINGS
RELAY SELECTION ON THE CHANNELS
Each receiver is able to recognize all four transmitter channels even simultaneously. The output relay
(two in the twin channel versions) is allocated to the required channel via a jumper to be inserted in the
plugs provided.
Fig. 6
- 28 -
OUTPUT CONTACT
The outputs are controlled by a normally open clean contact (i.e. free of other connections). If a normally
closed contact is required, this can be made by:
- Cutting the "N.A." jumper (Fig. 7)
- Soldering the "N.C." contacts with a drop of tin (Fig. 8)
Fig. 7
Fig. 8
- 29 -