LTC 8540/00 Series | Instruction Manual | Unpacking
1

UNPACKING

Unpack carefully. This is electronic equipment and
should be handled with care.
Check for the following items:
• Verify the model number of the unit
• One (1) cable with 9-pin D-sub connectors
• Connector Kit, containing ten (10) pieces of a
twelve (12) pin connector
• Installation manual
If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify your Bosch Security
Systems Sales Representative or Customer Service.
The shipping carton is the safest container in which the
unit may be transported. Save it for possible future
use.
2

SERVICE

If the unit ever needs repair service, the customer
should contact the nearest Bosch Security Systems, Inc.
Service Center for return authorization and shipping
instructions.

Service Centers

USA
Telephone: 800-366-2283 or 585-340-4162
Fax: 800-366-1329
Email: cctv.repair@us.bosch.com
Customer Service
Telephone: 800-289-0096
Fax: 585-223-9180
Email: security.sales@us.bosch.com
Technical Support
Telephone: 800-289-0096
Fax: 585-223-3508 or 717-735-6560
Email: technical.support@us.bosch.com
Repair Center
Telephone: 585-421-4220
Fax: 585-223-9180 or 717-735-6561
Email: security.repair@us.bosch.com
Canada
Telephone: 514-738-2434
Fax: 514-738-8480
Europe, Middle East & Asia Pacific Region
Telephone: 44 (0) 1495 274558
Fax: 44 (0) 1495 274280
Email: rmahelpdesk@solectron.com
Bosch Security Systems | December 13, 2007
3

DESCRIPTION

The LTC 8540/00 Alarm Interface Unit provides the
Allegiant® series of matrix switcher/controllers
(LTC 8500, LTC 8600, TC8700, and LTC 8800) with
the ability to automatically display video under alarm
conditions. The LTC 8540/00 accepts up to 64 contact
closures or logic level inputs from remote sensing
devices such as door contacts, PIRs, etc., and then
reports the "alarm" information to the Allegiant series
main CPU bay. Alarm inputs may be configured in
groups of 32 to accept either normally open or
normally closed contacts. The LTC 8540/00 also
provides eight relay closure outputs upon alarm
conditions
4

INSTALLATION

4. 1

Power/Data

An interface cable for data/power between the
LTC 8540/00 unit and the Allegiant CPU bay is
supplied. If required, the Alarm Interface Unit may
also be installed remotely using a user supplied Listed
Class 2 or equivalent 12 VAC or 12 VDC, 8 W power
source. A minimal 3 or 5 wire RS-232 interface would
then be required for communication to the Allegiant
CPU bay. If necessary, the supplied cable can be cut
and spliced to make the appropriate connections. A
table listing the unit's interface port pinouts can be
found at the end of this manual. Allegiant port pinouts
are listed in the QUICK REFERENCE MAIN BAY
REAR PANEL CONNECTOR PINOUTS section of
the Allegiant Series Installation and Operating
Instructions.
Caution: DO NOT connect an external
voltage source to this unit if it is already
connected directly to the Allegiant CPU bay
using the supplied cable.

4.2 Mounting Options

4.2. 1 Rack Mount

The LTC 8540/00 unit is supplied from the factory in
an enclosure suitable for rack mounting. The enclosure
is one EIA standard rack width by two rack heights.
Peel off the four rubber feet located on the bottom of
the enclosure before installing into console.
EN | 7