Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
GB
GB
Application
®
The GROHE Blue
cooler/carbonator is designed for use in
the private, non-commercial sector.
The cooler/carbonator works with environmentally-friendly
refrigerant.
Safety notes
This device is not intended for use by persons
(including children) with physical, sensory or mental
impairments or a lack of experience or knowledge
in using devices of this type.
Children must be supervised to ensure that they
do not play with the device.
Prevent danger resulting from damaged power
supply cables. In the case of damage, the mains
cable must be replaced by the manufacturer or his
customer service department, or an equally qualified
person.
CO
(carbon dioxide) is a gas and must not be
2
inhaled due to danger of suffocation. Only CO
cylinders up to max. 2 kg may be used. When
using these, the floor space must be at least 13 m
The CO
cylinder is pressurised. It must only be
2
operated in the vertical position and must be
secured against falling over.
Operation is only permissible in conjunction with
the accompanying adapter with pressure gauge.
• The mains plug provided (type EF plug) is only suitable for
use with Schuko (CEE 7/4) sockets.
• The system must not be transported with the CO
connected.
• The CO
cylinder must not be maintained or repaired by
2
unauthorised persons.
• During cleaning, do not spray the cooler/carbonator or the
plug directly or indirectly with water.
• The cooler/carbonator must be connected to a permanent
power supply.
• At the installation location, the cooler/carbonator, CO
cylinder and filter system must be protected from
mechanical damage, heat and direct sunlight.
Do not install near heat sources or an open fire.
• The cooler/carbonator must be placed in an upright position.
• The cooler/carbonator must not be opened.
• Installation of the fitting and cooler/carbonator with filter
cartridge is only permitted in frost-free rooms.
• The cooler/carbonator is only suitable for indoor use.
• Adequate ventilation must be ensured. If necessary, provide
ventilation grilles in the cover of the lower cabinet.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
Cooler/carbonator electrical data:
• Connection:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative air humidity:
• Refrigerant:
• Safety shut-off of pump:
Sanitary data:
• Cooler/carbonator cooled water capacity:
• System operating pressure:
• Flow rate at 0.3 MPa flow pressure:
• Ambient temperature:
• Temperature
– Cooler /carbonator water inlet:
– Cooled water temperature:
• Sound pressure level L
• Adjustable bypass, factory setting:
• Filter capacity at bypass setting 2
(Carbonate hardness 10 - 24 °KH):
• Water connection
– cooler/carbonator:
2
Electrical test data
.
2
• Software class:
• Contamination class:
• Rated surge voltage:
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Approval and conformity
This product conforms to the requirements of the
cylinder
relevant EU guidelines.
2
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica

Electrical installation

2
Electrical installation work must only be performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 60364-7-701 (corresponding
to VDE 0100 Part 701) as well as all national and
local regulations.
Installation
Refer to the installation dimensions on fold-out page I.
Install cooler/carbonator, see fold-out page I, Fig. [1].
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines. In order
to ensure that the cooling fluid has run back, the
cooler/carbonator may only be switched on following
a pause of 24 hours.
Connect cooler/carbonator and filter cartridge, see fold-out
page I, Figs. [2] to [4].
Open hot and cold water supply and check that
connections are watertight, see fold-out page II, Fig. [5].
Wall socket with earth wire, protected
via a 10 A fuse
230 V AC / 50 Hz
max. 75%
0.065 kg - R134a
approx. 4:30 min
max. 0.6 MPa
approx. 2 l/min
4 – 32 °C
max. 20 °C
approx. 5 – 10 °C
A (frestanding):
50 ± 4 dB
p
max. 600 liters
corresponds to max. 12 months
cold - blue
2,500 V
270 W
IP21
1.4 l
2
A
2
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis