Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Connect plug-in connection between fitting and cooler/
carbonator, see Fig. [6].
Establish voltage supply via mains plug, see Fig. [7].
The display illuminates and the remaining filter capacity is
displayed in percent.
Connect CO
cylinder, see Figs. [8] to [13].
2
Do not operate the valve on the back of the cooler/
carbonator as otherwise CO
2
- The valve is only needed when cleaning the cooler/
carbonator.
The fitting has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
The display in the handle illuminates blue.
®
If the Blue
handle is flashing red and E4 or E6 appears in
the display, the fitting and cooler/carbonator must be
synchronised as follows, see Fig. [14]:
• Press and hold the
and
flashes in the display.
• Press the
button until SE stops flashing.
• Release the
button, C- flashes in the display.
• Keep pressing the
or
button until H- flashes in the
display.
• Press the
button until H- stops flashing.
®
• Blue
handle synchronisation starts; HC appears in the
®
display and the Blue
handle lights up red.
®
• As soon as the Blue
handle lights up green, open the fitting
®
fully by turning the Blue
handle.
• As soon as the Blue
®
handle briefly flashes green, close the
fitting by turning the Blue
®
handle, HC flashes in the display.
• Confirm the setting by pressing the
appears.
• Release the
button.
The remaining filter capacity is displayed.
Commissioning
Control, see fold-out page II, Fig. [14].
The buttons have the following functions:
Filter replacement reset
Filter size selection
Carbonate hardness adjustment
Display, see Fig. [14].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator, see Fig. [15].
Set the filter size, see Fig. [14] and [16].
button for filter size selection:
• Press and hold
button once until the currently setted
value (e. g. F1) flashes in the display
• Press the
button and select the required value appears
- F1:
40 404 000
- F2:
40 430 000
- F3:
40 412 000
- F4:
40 404 001
- F5:
40 430 001
- F6:
40 412 001
- F7:
40 691 001 (Magnesium)
- F8:
40 547 001 (Activ carbon)
• Press and hold the
button until the required value stops
flashing
• Release the
button:
The remaining filter capacity is displayed.
5
will escape, see Fig. [9].
buttons simultaneously until SE
button longer, HC
Note: The various filter cartridges can be ordered at
www.grohe.com.
Set carbonate hardness at filter head, see Fig. [16].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page III.
Display and setting of carbonate hardness on cooler/
carbonator, see table column B on fold-out page III and
Fig. [14].
button for carbonate hardness adjustment:
• Press and hold the
button once until the currently setted
value (e. g. C3) flashes in the display
• Press the
button and select the required value:
- C4: carbonate hardness
- Factory setting:
C3: carbonate hardness
- C2: carbonate hardness
- C1: carbonate hardness
• Press and hold the
button until the setted value stops
flashing
• Release the
button.
The remaining filter capacity is displayed.
The liter capacity of the filter cartridge varies according to the
water hardness set and the size of the filter cartridge, see table
on fold-out page III.
The cooler/carbonator is set for operation with the 600 litre
filter cartridge (Prod no.: 40 404 001) at the factory.
For operation with other filter cartridges the cooler/carbonator
must be set out.
The fitting with cooler/carbonator is now fully installed and
ready for operation.

Maintenance

Resetting filter capacity after changing filter cartridge, see
fold-out page II, Fig. [14].
button for filter replacement reset:
• Press and hold
button until rF flashes in the display.
• Release the
button and press again until rF stops
flashing.
• Release the
button.
The remaining filter capacity is reset and then displayed
again.
Restore factory settings, see Fig. [14].
Reset
buttons to factory settings:
• Press and hold the
buttons simultaneously until PA
starts flashing in the display.
• Release the
buttons.
The remaining filter capacity is displayed.
Important:
Risk of damage!
Always disconnect the power supply and interrupt
the CO
supply before carrying out maintenance work
2
on the system. The plug-in connector can then be
disconnected, see fold-out page II, Figs. [6] and [7].
Inspect and clean all components and replace if necessary.
Assemble in reverse order.
9
(bypass 3)
10 - 24
(bypass 2)
25 - 29
(bypass1)
30
(bypass 0)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis