Herunterladen Diese Seite drucken

Eibenstock PLD 160 Originalbetriebsanleitung Seite 22

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Attention!
The PRCD protective switch must not lay in water.
!
PRCD protective switches must not be used to switch the tool on
and off.
Before starting your work, check the proper function by
pressing the TEST button.
Use only extension cable with sufficient cross-section (min. 2,5 mm
cross-section which is to small could lead to excessive power loss and to
overheating the motor and the cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
Prior to putting the tool into operation, check the mains voltage for
conformity with the requirements of the tool's nameplate. Voltage variations
between + 6 % and – 10 % are permissible. The tool includes a start-up
speed limiter to prevent fast expulsion fuses from unindented responding.
Additional Handle
For manual drilling, the PLD 160 may be used only together with
its additional handle which comes with the tools. Place it on the
gearing collar from the front and fix it by turning the handle in
direction of the arrow.
Switching ON and OFF
Short-time operation
ON:
Press the ON/OFF switch
OFF:
Release the ON/OFF switch
Long-time operation
ON:
Keeping the ON/Off switch pressed, push in the arrestor button.
OFF:
Press and release the ON/OFF switch again.
Attention!
Use the arrestor button only during operation with drill rig.
!
Its use during manual operation is not allowed.
If the machine stops for any reason or due to power failure,
immediately release the arrestor button by pressing the
ON/OFF switch. If this button is not released, the tool may
unintendedly restart if the PRCD protective switch is
operated and cause a danger to the user.
Cross section in sq. mm
1.5
20 m
50 m
21
2
). A
2.5
40 m
80 m

Werbung