Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of Outdoor Unit - Toshiba HWS-802H-E Installations-Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Air to Water Heat Pump
2. Serial installation of two or more units
300
or more
Serial installation at front and rear sides
Open the upper side and both right and left sides.
The height of obstacle at both front and rear sides
should be lower than the height of the outdoor unit.
▼ Standard installation
1000
300
or more
or more

Installation of Outdoor Unit

• Before installation, check strength and horizontality
of the base so that abnormal sound does not
generate.
• According to the following base diagram, fix the base
firmly with the anchor bolts.
(Anchor bolt, nut: M10 x 4 pairs)
Drain
nipple mounting hole
9-EN
or more
1500
2000
or more
or more
Drain hole
525
150
600
Drain hole
• As shown in the figure below, install the foundation
and vibration-proof rubbers to directly support the
bottom surface of the fixing leg that is in contact with
the bottom plate of the outdoor unit.
* When installing the foundation for an outdoor unit
with downward piping, consider the piping work.
300
Foundation
Foundation
200
or more
If only the end of the
fixing leg is
supported, it may be
deformed.
Foundation
Set the out margin of the anchor bolt to 15 mm or less.
150
– 10 –
Outdoor Unit Installation Manual
GOOD
Fixing leg
GOOD
Support the bottom surface of
the fixing leg in contact with
the bottom plate of the outdoor
unit.
NO GOOD
Absorb vibration
with vibration-
proof rubbers
Bottom plate
of outdoor unit
Do not support
the outdoor unit
only with the
fixing leg.
15 or less

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Hws-1102h-eHws-1402h-e

Inhaltsverzeichnis