DC voltage
Range
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
600 V overload protection; Impedance: 10 MΩ
* Accuracy: 40 - 60% of the measurement range; +1% outside of this range
Temperature
Range
-20.0 to +760.0 °C
-4.0 to +1400.0 °F
* Without sensor tolerance
* Accuracy: 40 - 60% of the measurement range; +1% outside of this range
Resistance
Range
400.0 Ω
4.000 kΩ
40.00 KΩ
400.0 KΩ
4.000 MΩ
40.00 MΩ
Overload protection 600 V; Measuring voltage: Approx. 0.5 V
*Accuracy: 40 - 60% of the measurement range; +1% outside of this range
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 °C
0.1 °F
Resolution
0.1 Ω
0.001 KΩ
0.01 KΩ
0.1 KΩ
0.001 MΩ
0.01 MΩ
Accuracy*
±(0.8% + 6)
±(1.2% + 5)
±(1.5% + 3)
Accuracy*
±(4% + 5 °C)
±(4% + 5 °C)
Accuracy*
±(1.5% + 6)
±(1.8% + 4)
±(2.8% + 5)
±(2.8% + 10)