NOTE: The 70 amp charge rate cycles bet-
ween 20 amps and 70 amps during the char-
ging process and the ammeter will show
this. This is a normal condition.
TIME (Timer – Range:
10 minutes to 120 minutes)
Used only in manual mode, the main func-
tion of the timer is to prevent overcharging
while allowing a battery time to obtain a sa-
tisfactory charge. To properly set the timer,
you must know the size of the battery in am-
pere hours or reserve capacity in minutes
and the state of charge.
Hold: This position defeats the timer func-
tion, allowing for continuous operation. Use
when you want to charge more than 2 hours.
Be sure to monitor the charging procedure
and stop when the battery is charged. Not
doing so may cause damage to your battery
or may cause other personal property dama-
ge or personal injury.
Mode Button
Use this button to select between the AU-
TOMATIC CHARGE, MANUAL CHARGE and
FLASH REPROGRAM function. See Operating
Instructions for details of these functions.
Battery Type/Desulfation Mode Button
Set the type of battery to be charged, or De-
sulfation Mode.
Ca/Ca (Calcium) – Calcium batteries are

acid batteries impregnated with calcium.
AGM/GEL (Absorbed Glass Mat/Gel

Cell) – AGM batteries have electrolyte
absorbed in separators consisting of a
sponge-like mass of matted glass fiber.
31
Gel batteries contain gelled electrolytes.
These batteries are sealed with valves
and should not be opened.
Desulfation Mode – If the battery is

left discharged for an extended period
of time, it could become sulfated and
not accept normal charge. If you select
, the charger will switch to a special
mode of operation designed for sulfated
batteries.
NOTE: When charging a battery that is not
marked, check the manual of the item which
uses the battery for the correct battery type.
Make sure the battery complies with the sa-
fety instructions in Section 2.3.
Charge Rate Button
Use this button to set the maximum charge
rate to one of the following:
4A Charge Rate – For charging small

batteries, such as those commonly used
in garden tractors, snowmobiles and
motorcycles.
20A and 70A Charge Rate – For charging

automotive and marine batteries.
NOTE: Charge rate cannot be selected while
using Desulfation Mode.

10. Operating instructions

Battery Information
This charger can be used with 12V batteries
with rated capacities of 12 Ah to 111 Ah.
Charger Operation