Troubleshooting

14. Troubleshooting
Note
The high limit safety cut-out can respond at temperatures
below –15 °C. The appliance may be subjected to these
temperatures during storage or transport.
Service code display
f Call up the service code display in the menu (see chapter
f
"Settings / Menu settings").
f The plugs are described in chapter "Specification / Wiring
f
diagrams and connections".
Fault
Code
No display.
Scale build-up symbol
"Ca" appears.
Service/fault symbol
2 Permanent set temperature
appears.
display.
4
16
128 The set values selected last
are active; possibly permanent
display 128.
Service/fault symbol
6 Permanent set temperature
flashes and the water
display.
does not heat up.
8 The heat-up symbol does not
appear.
32 Boil-dry protection.
64
38
| SHZ LCD
1 Reset key, high limit safety cut-out
2 High limit safety cut-out
Cause
There is no power.
There is no connection to the electronic assem-
bly for operation.
The electronic assembly for operation is faulty. Check the electronic assembly for operation and
The flanged immersion heater is scaled up.
The temperature sensor is faulty.
The impressed current anode is faulty.
Communication between the electronic assem-
blies for control unit and operation is faulty.
The temperature sensor is faulty.
The high limit safety cut-out has responded be-
cause the controller is faulty.
The high limit safety cut-out has responded
because the temperature has dropped below
-15 °C.
The rapid heating does not switch on.
The flanged immersion heater is faulty.
There is no water in the water heater.
There is no anode current.
The replaceable fine-wire fuse has tripped.
The relay is faulty.
1
2
Remedy
Connect the power supply.
Check whether plug X2 is properly inserted.
replace if required.
Descale the flanged immersion heater. The
symbol is automatically reset.
Check whether plug X10 is properly inserted.
Check the temperature sensor.
Check whether plug X7 is properly inserted.
Check the impressed current anode and wiring.
Check whether plugs X2 are inserted properly
in both assemblies.
Check the assemblies and the connecting cable.
Check whether plug X10 is properly inserted.
Check the temperature sensor.
Remedy the cause of the fault. Replace the high
limit safety cut-out.
Press the reset button
(see diagram).
Check the key.
Replace the flanged immersion heater.
Fill the water heater.
Check whether plug X7 is properly inserted.
Check the impressed current anode and wiring.
Check the replaceable fine-wire fuse.
Replace the electronic assembly for the control
unit.