Herunterladen Inhalt Inhalt Diese Seite drucken

Setting The Distance From The Absolute Zero Point Of The Scale To The Cutting Datum Point - Sony LH51 Bedienungsanleitung

Digital readout
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5-1-4. Setting the distance from the absolute zero point of the scale to the cutting datum point

• After completing 5-1-3, press the axis selector key to select the mode for setting the distance
• Number keys and the
• If the LH51/52 counter unit is used to replace another counter unit, and you have already made
• The distance is factory set to 0.0000 mm.
Example : Input to the first axis
Example: To set the distance to 10 mm
X
1
0
P
• If the distance from the absolute zero point of the scale to the datum point has not been
• Numbers that can be input vary according to the resolution.
• The ABS and INC indicator lights and REF flashes during number input. When the Preset key is
from the absolute zero point of the scale to a datum point.
key are used to set and change the distance from the absolute zero
P
point to a datum point.
a note of the distance, the distance can be set by following the procedure below.
Operating Procedure
Select first axis input.
Press the number keys.
Press the Preset key to complete the setting.
Note
measured, this initial setting is not necessary as the distance will be automatically stored by
performing the operations outlined in sub-section 5-7-3 "Setting of datum point" (page 43).
Example: In the case of 0.0005 mm:–999.9995 to +999.9995
In the case of 0.01 mm:–99999.99 to +99999.99
If the resolution is made finer after a large value is input with a coarse resolution, an overflow
alarm display will result for the offset value ∆Y.
pressed to confirm the number, the ABS and INC indicator turns off and REF lights steadily.
Display
ABS, INC lights up
ABS, INC lights up
ABS, INC turns off
REF
Lights up
REF
Flashes
REF
Lights up
17

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lh52

Inhaltsverzeichnis